+19 17Th Edition Bathroom Zones Ideas


+19 17Th Edition Bathroom Zones Ideas. This is done to avoid any splash backs onto the socket. The area stretching 0.6m outside the perimeter of the bath to a height of 2.25m.

Bathroom Zones as defined in BS7671
Bathroom Zones as defined in BS7671 from flameport.com

The area stretching 0.6m outside the perimeter of the bath to a height of 2.25m. Shown green in the diagram. A switch should be at least 0 6 m from the edge of the bath or shower outside the zones and must be suitable for the location.

Zone 2 Also Includes Any Recessed Window With A Sill Next To The Bath


The installation of electrical devices in bathrooms and shower rooms is regulated in section 701 of bs 7671:2008, and part p of the building regulations. Under the 18th edition bs 7671 will this gas pipe be an extraneous conductive. As with zone 1, the minimum rating for this zone is ipx4.

The Exterior Of The Bath Or Shower Tray To A Height Of 2.25 Metres Above The Finished Floor Level.


Note this is measured from the floor level, not the interior of the bath. Zones are now 1, 2 and 3. Any fitting used in this bathroom zone must be low voltage, (max 12v) and be rated at least ip67 which is total immersion proof.

The 17Th Edition, Published In 2008, Introduced A Number Of Amendments.


For full information please refer to bs7671:2008. A height of 2.25m from the floor. Zone 2 (regulation 701.32.4) this is defined as extending horizontally from the edge of zone 1 by a further 0.6m and vertically to the limiting 2.25m or height of the highest water outlet.

These Included Changes To The Zonal System, Rcd Protection On All Bathroom Circuits, And 230 V Socket Outlets Permitted 3 M Horizontally From The Boundary Of Zone 1;


When the size of bathroom extends beyond zone 2, portable equipment is allowed, however they should be positioned such that that their flex length does not enable them to be used in zone 2. Fittings in zone 1 need a minimum ipx4 rating. If there is no shower tray present then this (and zone 1) extend to 1.2m from the ā€˜fixed water outlet’ or shower head.

Electrical Safety Zones 0 And 1 For Showers Without Shower Basins Or Trays.


For a bathroom is 2.25m above the finished floor level by the same width as the bath. (we do not currently have any fittings that are suitable for zone 0) zone 1. The zones the 17th edition of the iee wiring regulations redefined the zones for electrical equipment in bathrooms and.